Discharge Flange
DN 32 up to DN 250 mm
Capacity
up to 1000 m3/h
Head
up to 550 m
Speed
up to 2900 rpm
Operating Temperature
-10 °C up to +140 °C
Casing Pressure (Pmax)
25 - 63 bar

Horizontal ring section, multistage, centrifugal pumps with closed impellers and diffusers.

Discharge Flange
DN 32 up to DN 125 mm
Capacity
up to 350 m3/h
Head
up to 105 m
Speed
up to 2900 rpm
Operating Temperature
up to 350 °C
Casing Pressure (Pmax)
10-16 bar

Horizontal, radially split volute casing type, single stage, end suction, air cooled centrifugal pumps with closed impeller.

Discharge Flange
DN 50 up to DN 300 mm
Capacity
up to 1600 m3/h
Head
up to 95 m
Speed
up to 2900 rpm
Operating Temperature
up to 40 °C
Casing Pressure (Pmax)
10 bar

Vertical, wide volute casing, single stage, end suction centrifugal pump with enclosed, semi-open or vortex types impeller.

Discharge Flange
DN 40 up to DN 200 mm
Capacity
up to 500 m3/h
Head
up to 95 m
Speed
up to 2900 rpm
Motor Rating
up to 55 kW
Operating Temperature
-10 °C up to +110 °C
Casing Pressure (Pmax)
10 - 16 bar

Close-coupled, volute casing, single stage, in-line centrifugal pump with closed impeller.

Discharge Flange
DN 65 up to DN 600 mm
Capacity
up to 6000 m3/h
Head
up to 180 m
Speed
up to 2900 rpm
Operating Temperature
-10 °C up to 110 °C
Casing Pressure (Pmax)
16 - 25 bar

Handled Liquids: Clean or slightly contaminated low viscosity liquids without solid & fibrous particles.

Installation
Pendent
Material
Chrome Plated
Working Pressure
Min. 0.1 MPA
Size
½" NPT Threaded

This water mist fire sprinkler head features a closed design for efficient water distribution and a chrome-plated finish for durability. With a spraying angle of 120°, it effectively suppresses fires...

Temperature
68ËšC (155ËšF)
Type
Pendent
Material
Chrome

Crafted from chrome, this pendent fire sprinkler provides reliable fire protection in commercial and residential settings. Its quick response time and certifications from UL, C-UL, FM, LPCB, and VdS...

Temperature
68ËšC (155ËšF)
Type
Sidewall
Material
Brass / Chrome

This sidewall fire sprinkler has a sleek brass/chrome construction. Engineered to respond quickly to rising temperatures, it effectively controls fires and is certified by by reputable organizations.

Temperature
68ËšC (155ËšF)
Type
Pendent

This pendent fire sprinkler is designed to activate when the temperature reaches a certain threshold, releasing water to suppress fires. Made of durable materials and certified by reputable...

Temperature
68ËšC (155ËšF)
Type
Upright
Material
Brass / Chrome

Designed for fire suppression, this upright fire sprinkler features a brass/chrome construction and a glass bulb for temperature sensitivity. With UL, FM, and other certifications, it meets safety...

Type
Wet Headed
Body
Carbon Steel
Working Pressure
PN16
Diameter of Hydrant Body
DN 150

The Hydrant is composed of 2 Hose Connection and 1 Monitor.
Type: Non-Self Drainage Type.

Body
Aluminum
Working Pressure
PN10

Crafted from aluminum, this standpipe ensures optimal water flow for hydrants. Its standardized outlet size makes it compatible with various systems, while its sturdy construction ensures durability.

Body
Aluminum
Working Pressure
PN10

Designed for efficient water distribution, this manifold features a durable aluminum body with dual outlet valves. It ensures reliable performance with its standard specifications.

Type
Dry Barrel
Body
Cast Iron
Working Pressure
16 bar

Crafted from cast iron for durability and resilience. Designed to withstand high working pressure. Compliant with standards and certified, this hydrant ensures reliable performance in fire suppression...

Type
Wet Barrel
Body
Cast Iron
Working Pressure
16 bar

Constructed from sturdy cast iron, this fire hydrant delivers reliable performance. With a fusion-bonded red epoxy coating, it provides corrosion resistance and longevity in fire suppression...

Type
Wet Barrel
Body
Carbon Steel
Working Pressure
16 bar
Connection
Flanged

Designed for durability, this carbon steel fire hydrant has a working pressure of 16 bar and a flanged connection for easy installation. Protected by a fusion-bonded red epoxy coating, it offers long...

Type
Wet Barrel
Body
Carbon Steel - SCH40
Working Pressure
12 bar
Test Pressure
16 bar

This fire hydrant, constructed from carbon steel, offers reliable performance. With a length of 1000mm and a fusion-bonded red coating, it meets ISO standards 9001:2015, 14001:2015, and 45001:2018.

Type
Wet Barrel
Body
Carbon Steel - SCH40
Working Pressure
12 bar
Test Pressure
16 bar

This fire hydrant, constructed from carbon steel, offers reliable performance. With a length of 1000mm and a fusion-bonded red coating, it meets ISO standards 9001:2015, 14001:2015, and 45001:2018.

Type
Wet Barrel
Body
Cast Iron
Working Pressure
16 bar
Connection
Flanged

The overground wet barrel fire hydrant is constructed from durable cast iron, featuring a flanged connection and a 4" outlet, it ensures efficient water distribution.

Type
Wet Barrel
Body
Cast Iron
Working Pressure
16 bar
Test Pressure
20 bar

Crafted from cast iron, this wet barrel fire hydrant ensures dependable performance in firefighting scenarios. It's engineered to withstand high-pressure environments