Indicator
Supports up to 3 detector status indicators
LED
LED, Maximum Visibility
Installation
Surface Mounting

FRL-1 is a fire remote indicator with 1 input. The device repeats the status of 1 or several automatic fire detectors (up to 3) SensoMAG or SensoIRIS series. The remote indicator operates with limited...

Standard
EN54 – 3
Sound Output
96 dB
LED
LED Strobe, Status Indicator
Protection
IP 54

SF 200 is an outdoor conventional piezo siren. The siren is equipped with 2 LED flash indicators and 1 status indicator.

Standard
EN54 – 3
Type
Piezo Loudspeaker, 32 Tones
Sound Level
Selectable by Jumpers: 94 to 102dB
Operating Voltage
20 - 28 VDC

SF100 RSST is a conventional wall mount sounder and strobe, designed for installing in conventional fire alarm systems. Supports 32 different tone types and two sound levels, controlled by jumpers.

Standard
EN54 – 11
LED
LED Indication
Siren Output
Indication on Every 8 Seconds
Installation
Surface Mounting

SensoMAG MCP50 is a manual call point designed to work in conventional fire alarm systems. The call point has a resettable fragile working element, that sends alarm signal to the fire alarm panel...

Standard
EN54 – 5/7
LED
LED Indication, 360° Visibility
Siren Output
Indication Every 8 Seconds
Temperature Detection
Above 60°C

SensoMAG M40 is a combined (optical-smoke and rate-of-rise) detector with digital processing algorithm, class A1/R. The integrated automatic drift compensation operation algorithm reduces...

Standard
EN54 – 5 Certified
LED
LED Indication, 360° Visibility
Siren Output
Indication Every 8 Seconds
Power Input
9-30 VDC

SensoMAG F10 is a fixed temperature detector with digital processing algorithm. The detector is designed to detect temperatures above 60°C (class A2/S, according EN54-5).

Standard
EN54 – 7 Certified
LED
LED Indication, 360° Visibility
Siren Output
Indication on Every 8 Seconds
Operating Voltage
9-30 VDC

SensoMAG S30 is an optical-smoke detector with digital processing algorithm. The detector is designed to detect smoke in the very early stage of the fire situation.

Zone Capacity
8 to 16
Standard
EN54 2/4
Main Power Supply
~230 VAC ± 10%
Siren Output
4 x 300 mA

MAG8Plus is a conventional fire detection and indication panel certificated to EN54-2/4. The panel has 8 fixed zones and is expanded up to 16 .

Zone Capacity
8
Standard
EN54 2/4
Main Power Supply
~230 VAC ± 10%
Siren Output
2 x 24V / 0.5A

MAG8 is a conventional fire alarm panel certified to EN54-2/4 standard, providing 8 fixed zones and each zone 32 sensors. Up to 20 (32 SensoMAG Series) fire detectors can be connected to every fire...

Zone Capacity
4
Standard
EN54 2/4
Main Power Supply
~230 VAC ± 10%
Siren Output
2 x 300 mA

MAG4 is a conventional fire alarm panel certified to EN54-2/4 standard, providing 4 fixed zones and each zone 32 sensors. Up to 20 (32 SensoMAG Series) fire detectors can be connected to every fire...

Zone Capacity
2
Standard
EN54 2/4
Main Power Supply
~230 VAC ± 10%
Siren Output
2 x 300 mA

MAG 2 is a conventional fire alarm panel certified to EN54-2/4 standard, providing 2 fixed zones and each zone 32 sensors. Up to 20 (32 SensoMAG Series) fire detectors can be connected to every fire...

Motor Power
55 - 90 kW
Motor Speed
735 rpm
Service Liquid Flow
max 150 - 210 lt/min
Suction Capacity
1600 - 3600 m3/h

Sing Stage Liquid Ring Vacuum Pumps are used for pumping dry and wet gases, small quantities of liquid can be handled. They are used in the areas at which vacuum needed between the pressures 1013 to...

Motor Power
30 - 45 kW
Motor Speed
980 rpm
Service Liquid Flow
max 85 - 100 lt/min
Suction Capacity
880 - 1700 m3/h

Single Stage Liquid Ring Vacuum Pumps are used for pumping dry and wet gases, small quantities of liquid can be handled. They are used in the areas at which vacuum needed between the pressures 1013 to...

Motor Power
15 - 22 kW
Motor Speed
1450 rpm
Service Liquid Flow
max 50 - 60 lt/min
Suction Capacity
450 - 830 m3/h

Single Stage Liquid Ring Vacuum Pumps are used for pumping dry and wet gases, small quantities of liquid can be handled. They are used in the areas at which vacuum needed between the pressures 1013 to...